Eaton SMBJ8.5A TVS Diode, 14.4 V Clamp
Eaton SMBJ8.5A TVS Diode, 14.4 V Clamp

Eaton SMBJ8.5A TVS Diode, 14.4 V Clamp

Share
SMBJ8.5A: transient voltage suppressor diode, 8.5 V standoff, 14.4 V clamp, 41.7 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ8.5A TVS Diode, 14.4 V Clamp

    SMBJ8.5A at a glance: transient voltage suppressor diode, 8.5 V standoff, 14.4 V clamp, 41.7 A pulse, 600 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJ8.5A
    Standoff voltage (VR)8.5 V
    Leakage current at VR30 uA
    Breakdown voltage at IT9.44 V to 10.4 V
    Test current (IT)1 mA
    Clamping voltage at IPP14.4 V
    Peak pulse current41.7 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.17 percent, from 9.44 V to 10.4 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 8.5 V standing the leakage is at most 30 uA, so the part draws 0.255 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 12 of 151 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.