Eaton SMBJE11A Transient Voltage Suppressor 11 V
Eaton SMBJE11A Transient Voltage Suppressor 11 V

Eaton SMBJE11A Transient Voltage Suppressor 11 V

Share
SMBJE11A: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 33 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJE11A Transient Voltage Suppressor 11 V

    SMBJE11A at a glance: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 33 A pulse, 600 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMBJE11A
    Standoff voltage (VR)11 V
    Leakage current at VR1 uA
    Breakdown voltage at IT12.2 V to 13.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP18.2 V
    Peak pulse current33 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.66 percent, from 12.2 V to 13.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 11 V standing the leakage is at most 1 uA, so the part draws 0.011 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 20 of 151 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products