Eaton SMBJE11CA 11 V 600 W TVS Diode
Eaton SMBJE11CA 11 V 600 W TVS Diode

Eaton SMBJE11CA 11 V 600 W TVS Diode

Share
SMBJE11CA: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 33 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJE11CA 11 V 600 W TVS Diode

    SMBJE11CA at a glance: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 33 A pulse, 600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMBJE11CA
    Standoff voltage (VR)11 V
    Leakage current at VR1 uA
    Breakdown voltage at IT12.2 V to 13.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP18.2 V
    Peak pulse current33 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.66 percent, from 12.2 V to 13.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 11 V standing the leakage is at most 1 uA, so the part draws 0.011 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 22 of 167 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.