Eaton SMBJE160A TVS Diode, 259 V Clamp
Eaton SMBJE160A TVS Diode, 259 V Clamp

Eaton SMBJE160A TVS Diode, 259 V Clamp

Share
SMBJE160A: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 2.3 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJE160A TVS Diode, 259 V Clamp

    SMBJE160A at a glance: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 2.3 A pulse, 600 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJE160A
    Standoff voltage (VR)160 V
    Leakage current at VR1 uA
    Breakdown voltage at IT178 V to 197 V
    Test current (IT)1 mA
    Clamping voltage at IPP259 V
    Peak pulse current2.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.67 percent, from 178 V to 197 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 160 V standing the leakage is at most 1 uA, so the part draws 0.16 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 118 of 151 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.