| Parameter | Value |
|---|---|
| Orderable part number | SMBJE24A |
| Standoff voltage (VR) | 24 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 26.7 V to 29.5 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 38.9 V |
| Peak pulse current | 15.4 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 600 W |
| Package | SMB (DO-214AA) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11214 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11214; the package line above is the
body the part is built in.
A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.
The breakdown window spans 10.49 percent, from 26.7 V to 29.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 24 V standing the leakage is at most 1 uA, so the part draws 0.024 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMBJ family this is item 49 of 151 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd