Eaton SMBJE440CA 440 V 600 W TVS Diode
Eaton SMBJE440CA 440 V 600 W TVS Diode

Eaton SMBJE440CA 440 V 600 W TVS Diode

Share
SMBJE440CA: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 0.8 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJE440CA 440 V 600 W TVS Diode

    SMBJE440CA at a glance: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 0.8 A pulse, 600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJE440CA
    Standoff voltage (VR)440 V
    Leakage current at VR1 uA
    Breakdown voltage at IT492 V to 543 V
    Test current (IT)1 mA
    Clamping voltage at IPP713 V
    Peak pulse current0.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.37 percent, from 492 V to 543 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 440 V standing the leakage is at most 1 uA, so the part draws 0.44 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 167 of 167 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.