SMBJE5.0A: transient voltage suppressor diode, 5 V standoff, 9.2 V clamp, 65.2 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJE5.0A TVS Diode, 9.2 V Clamp

    SMBJE5.0A at a glance: transient voltage suppressor diode, 5 V standoff, 9.2 V clamp, 65.2 A pulse, 600 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMBJE5.0A
    Standoff voltage (VR)5 V
    Leakage current at VR120 uA
    Breakdown voltage at IT6.4 V to 7 V
    Test current (IT)10 mA
    Clamping voltage at IPP9.2 V
    Peak pulse current65.2 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 9.375 percent, from 6.4 V to 7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 5 V standing the leakage is at most 120 uA, so the part draws 0.6 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 1 of 151 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd