Eaton SMBJE5.0CA 5 V 600 W TVS Diode
Eaton SMBJE5.0CA 5 V 600 W TVS Diode

Eaton SMBJE5.0CA 5 V 600 W TVS Diode

Share
SMBJE5.0CA: transient voltage suppressor diode, 5 V standoff, 9.2 V clamp, 65.2 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJE5.0CA 5 V 600 W TVS Diode

    SMBJE5.0CA at a glance: transient voltage suppressor diode, 5 V standoff, 9.2 V clamp, 65.2 A pulse, 600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMBJE5.0CA
    Standoff voltage (VR)5 V
    Leakage current at VR120 uA
    Breakdown voltage at IT6.4 V to 7 V
    Test current (IT)10 mA
    Clamping voltage at IPP9.2 V
    Peak pulse current65.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 9.375 percent, from 6.4 V to 7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 5 V standing the leakage is at most 120 uA, so the part draws 0.6 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 3 of 167 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd