Eaton SMBJE51CA 51 V 600 W TVS Diode
Eaton SMBJE51CA 51 V 600 W TVS Diode

Eaton SMBJE51CA 51 V 600 W TVS Diode

Share
SMBJE51CA: transient voltage suppressor diode, 51 V standoff, 82.4 V clamp, 7.3 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJE51CA 51 V 600 W TVS Diode

    SMBJE51CA at a glance: transient voltage suppressor diode, 51 V standoff, 82.4 V clamp, 7.3 A pulse, 600 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJE51CA
    Standoff voltage (VR)51 V
    Leakage current at VR1 uA
    Breakdown voltage at IT56.7 V to 62.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP82.4 V
    Peak pulse current7.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.58 percent, from 56.7 V to 62.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 51 V standing the leakage is at most 1 uA, so the part draws 0.051 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 86 of 167 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd