Eaton SMBJE54CA 54 V 600 W TVS Diode
Eaton SMBJE54CA 54 V 600 W TVS Diode

Eaton SMBJE54CA 54 V 600 W TVS Diode

Share
SMBJE54CA: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 6.9 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJE54CA 54 V 600 W TVS Diode

    SMBJE54CA at a glance: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 6.9 A pulse, 600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJE54CA
    Standoff voltage (VR)54 V
    Leakage current at VR1 uA
    Breakdown voltage at IT60 V to 66.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP87.1 V
    Peak pulse current6.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.5 percent, from 60 V to 66.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 54 V standing the leakage is at most 1 uA, so the part draws 0.054 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 89 of 167 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products