| Parameter | Value |
|---|---|
| Orderable part number | SMBJE64CA |
| Standoff voltage (VR) | 64 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 71.1 V to 78.6 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 103 V |
| Peak pulse current | 5.8 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 600 W |
| Package | SMB (DO-214AA) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11214 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11214; the package line above is the
body the part is built in.
The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.
The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 64 V standing the leakage is at most 1 uA, so the part draws 0.064 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMBJ family this is item 100 of 167 in the Eaton catalogue.
The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.