Eaton SMBJE75A Transient Voltage Suppressor 75 V
Eaton SMBJE75A Transient Voltage Suppressor 75 V

Eaton SMBJE75A Transient Voltage Suppressor 75 V

Share
SMBJE75A: transient voltage suppressor diode, 75 V standoff, 121 V clamp, 5 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJE75A Transient Voltage Suppressor 75 V

    SMBJE75A at a glance: transient voltage suppressor diode, 75 V standoff, 121 V clamp, 5 A pulse, 600 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMBJE75A
    Standoff voltage (VR)75 V
    Leakage current at VR1 uA
    Breakdown voltage at IT83.3 V to 92.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP121 V
    Peak pulse current5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.56 percent, from 83.3 V to 92.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 75 V standing the leakage is at most 1 uA, so the part draws 0.075 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 91 of 151 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd