Eaton SMBJE9.0CA 9 V 600 W TVS Diode
Eaton SMBJE9.0CA 9 V 600 W TVS Diode

Eaton SMBJE9.0CA 9 V 600 W TVS Diode

Share
SMBJE9.0CA: transient voltage suppressor diode, 9 V standoff, 15.4 V clamp, 39 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJE9.0CA 9 V 600 W TVS Diode

    SMBJE9.0CA at a glance: transient voltage suppressor diode, 9 V standoff, 15.4 V clamp, 39 A pulse, 600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJE9.0CA
    Standoff voltage (VR)9 V
    Leakage current at VR5 uA
    Breakdown voltage at IT10 V to 11.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP15.4 V
    Peak pulse current39 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11214

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11214; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 11 percent, from 10 V to 11.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 9 V standing the leakage is at most 5 uA, so the part draws 0.045 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 17 of 167 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products