Eaton SMCJ11A TVS Diode, 18.2 V Clamp
Eaton SMCJ11A TVS Diode, 18.2 V Clamp

Eaton SMCJ11A TVS Diode, 18.2 V Clamp

Share
SMCJ11A: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 82.5 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ11A TVS Diode, 18.2 V Clamp

    SMCJ11A at a glance: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 82.5 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJ11A
    Standoff voltage (VR)11 V
    Leakage current at VR1 uA
    Breakdown voltage at IT12.2 V to 13.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP18.2 V
    Peak pulse current82.5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.66 percent, from 12.2 V to 13.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 11 V standing the leakage is at most 1 uA, so the part draws 0.011 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 19 of 155 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products