Eaton SMCJ14CA 14 V 1500 W TVS Diode
Eaton SMCJ14CA 14 V 1500 W TVS Diode

Eaton SMCJ14CA 14 V 1500 W TVS Diode

Share
SMCJ14CA: transient voltage suppressor diode, 14 V standoff, 23.2 V clamp, 64.7 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton SMCJ14CA 14 V 1500 W TVS Diode

    SMCJ14CA at a glance: transient voltage suppressor diode, 14 V standoff, 23.2 V clamp, 64.7 A pulse, 1500 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJ14CA
    Standoff voltage (VR)14 V
    Leakage current at VR1 uA
    Breakdown voltage at IT15.6 V to 17.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP23.2 V
    Peak pulse current64.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.26 percent, from 15.6 V to 17.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 14 V standing the leakage is at most 1 uA, so the part draws 0.014 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 25 of 155 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products