Eaton SMCJ160CA 160 V 1500 W TVS Diode
Eaton SMCJ160CA 160 V 1500 W TVS Diode

Eaton SMCJ160CA 160 V 1500 W TVS Diode

Share
SMCJ160CA: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 5.8 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton SMCJ160CA 160 V 1500 W TVS Diode

    SMCJ160CA at a glance: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 5.8 A pulse, 1500 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMCJ160CA
    Standoff voltage (VR)160 V
    Leakage current at VR1 uA
    Breakdown voltage at IT178 V to 197 V
    Test current (IT)1 mA
    Clamping voltage at IPP259 V
    Peak pulse current5.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.67 percent, from 178 V to 197 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 160 V standing the leakage is at most 1 uA, so the part draws 0.16 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 120 of 155 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products