Eaton SMCJ180AH Transient Voltage Suppressor 180 V
Eaton SMCJ180AH Transient Voltage Suppressor 180 V

Eaton SMCJ180AH Transient Voltage Suppressor 180 V

Share
SMCJ180AH: transient voltage suppressor diode, 180 V standoff, 292 V clamp, 5.2 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ180AH Transient Voltage Suppressor 180 V

    SMCJ180AH at a glance: transient voltage suppressor diode, 180 V standoff, 292 V clamp, 5.2 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJ180AH
    Standoff voltage (VR)180 V
    Leakage current at VR1 uA
    Breakdown voltage at IT201 V to 222 V
    Test current (IT)1 mA
    Clamping voltage at IPP292 V
    Peak pulse current5.2 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1064

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1064; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.45 percent, from 201 V to 222 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 180 V standing the leakage is at most 1 uA, so the part draws 0.18 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 127 of 155 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd