| Parameter | Value |
|---|---|
| Orderable part number | SMCJ180CA |
| Standoff voltage (VR) | 180 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 201 V to 222 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 292 V |
| Peak pulse current | 5.1 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 1500 W |
| Package | SMC (DO-214AB) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1563 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1563; the package line above is the
body the part is built in.
A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.
The breakdown window spans 10.45 percent, from 201 V to 222 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 180 V standing the leakage is at most 1 uA, so the part draws 0.18 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMCJ family this is item 126 of 155 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd