Eaton SMCJ190AH TVS Diode, 307 V Clamp
Eaton SMCJ190AH TVS Diode, 307 V Clamp

Eaton SMCJ190AH TVS Diode, 307 V Clamp

Share
SMCJ190AH: transient voltage suppressor diode, 190 V standoff, 307 V clamp, 4.9 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ190AH TVS Diode, 307 V Clamp

    SMCJ190AH at a glance: transient voltage suppressor diode, 190 V standoff, 307 V clamp, 4.9 A pulse, 1500 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMCJ190AH
    Standoff voltage (VR)190 V
    Leakage current at VR1 uA
    Breakdown voltage at IT211 V to 234 V
    Test current (IT)1 mA
    Clamping voltage at IPP307 V
    Peak pulse current4.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1064

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1064; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.9 percent, from 211 V to 234 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 190 V standing the leakage is at most 1 uA, so the part draws 0.19 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 130 of 155 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products