| Parameter | Value |
|---|---|
| Orderable part number | SMCJ190CAH |
| Standoff voltage (VR) | 190 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 211 V to 234 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 307 V |
| Peak pulse current | 4.9 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 1500 W |
| Package | SMC (DO-214AB) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1064 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1064; the package line above is the
body the part is built in.
These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.
The breakdown window spans 10.9 percent, from 211 V to 234 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 190 V standing the leakage is at most 1 uA, so the part draws 0.19 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMCJ family this is item 130 of 155 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.