Eaton SMCJ200AH Transient Voltage Suppressor 200 V
Eaton SMCJ200AH Transient Voltage Suppressor 200 V

Eaton SMCJ200AH Transient Voltage Suppressor 200 V

Share
SMCJ200AH: transient voltage suppressor diode, 200 V standoff, 324 V clamp, 4.7 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ200AH Transient Voltage Suppressor 200 V

    SMCJ200AH at a glance: transient voltage suppressor diode, 200 V standoff, 324 V clamp, 4.7 A pulse, 1500 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMCJ200AH
    Standoff voltage (VR)200 V
    Leakage current at VR1 uA
    Breakdown voltage at IT224 V to 247 V
    Test current (IT)1 mA
    Clamping voltage at IPP324 V
    Peak pulse current4.7 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1064

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1064; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.27 percent, from 224 V to 247 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 200 V standing the leakage is at most 1 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 133 of 155 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products