Eaton SMCJ20A TVS Diode, 32.4 V Clamp
Eaton SMCJ20A TVS Diode, 32.4 V Clamp

Eaton SMCJ20A TVS Diode, 32.4 V Clamp

Share
SMCJ20A: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 46.3 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ20A TVS Diode, 32.4 V Clamp

    SMCJ20A at a glance: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 46.3 A pulse, 1500 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMCJ20A
    Standoff voltage (VR)20 V
    Leakage current at VR1 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP32.4 V
    Peak pulse current46.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    What the Numbers Mean

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 1 uA, so the part draws 0.02 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 39 of 155 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.