Eaton SMCJ220AH Transient Voltage Suppressor 220 V
Eaton SMCJ220AH Transient Voltage Suppressor 220 V

Eaton SMCJ220AH Transient Voltage Suppressor 220 V

Share
SMCJ220AH: transient voltage suppressor diode, 220 V standoff, 356 V clamp, 4.2 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ220AH Transient Voltage Suppressor 220 V

    SMCJ220AH at a glance: transient voltage suppressor diode, 220 V standoff, 356 V clamp, 4.2 A pulse, 1500 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMCJ220AH
    Standoff voltage (VR)220 V
    Leakage current at VR1 uA
    Breakdown voltage at IT246 V to 272 V
    Test current (IT)1 mA
    Clamping voltage at IPP356 V
    Peak pulse current4.2 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1064

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1064; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.57 percent, from 246 V to 272 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 220 V standing the leakage is at most 1 uA, so the part draws 0.22 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 139 of 155 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.