Eaton SMCJ40AH TVS Diode, 64.5 V Clamp
Eaton SMCJ40AH TVS Diode, 64.5 V Clamp

Eaton SMCJ40AH TVS Diode, 64.5 V Clamp

Share
SMCJ40AH: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 23.3 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ40AH TVS Diode, 64.5 V Clamp

    SMCJ40AH at a glance: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 23.3 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJ40AH
    Standoff voltage (VR)40 V
    Leakage current at VR1 uA
    Breakdown voltage at IT44.4 V to 49.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP64.5 V
    Peak pulse current23.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1064

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1064; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.59 percent, from 44.4 V to 49.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 40 V standing the leakage is at most 1 uA, so the part draws 0.04 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 64 of 155 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.