Eaton SMCJ440A TVS Diode, 713 V Clamp
Eaton SMCJ440A TVS Diode, 713 V Clamp

Eaton SMCJ440A TVS Diode, 713 V Clamp

Share
SMCJ440A: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 2.1 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ440A TVS Diode, 713 V Clamp

    SMCJ440A at a glance: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 2.1 A pulse, 1500 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMCJ440A
    Standoff voltage (VR)440 V
    Leakage current at VR1 uA
    Breakdown voltage at IT492 V to 543 V
    Test current (IT)1 mA
    Clamping voltage at IPP713 V
    Peak pulse current2.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.37 percent, from 492 V to 543 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 440 V standing the leakage is at most 1 uA, so the part draws 0.44 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 153 of 155 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.