Eaton SMCJ58A TVS Diode, 93.6 V Clamp
Eaton SMCJ58A TVS Diode, 93.6 V Clamp

Eaton SMCJ58A TVS Diode, 93.6 V Clamp

Share
SMCJ58A: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 16.1 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ58A TVS Diode, 93.6 V Clamp

    SMCJ58A at a glance: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 16.1 A pulse, 1500 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMCJ58A
    Standoff voltage (VR)58 V
    Leakage current at VR1 uA
    Breakdown voltage at IT64.4 V to 71.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP93.6 V
    Peak pulse current16.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.56 percent, from 64.4 V to 71.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 58 V standing the leakage is at most 1 uA, so the part draws 0.058 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 81 of 155 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products