Eaton SMCJ6.0A TVS Diode, 10.3 V Clamp
Eaton SMCJ6.0A TVS Diode, 10.3 V Clamp

Eaton SMCJ6.0A TVS Diode, 10.3 V Clamp

Share
SMCJ6.0A: transient voltage suppressor diode, 6 V standoff, 10.3 V clamp, 145.7 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ6.0A TVS Diode, 10.3 V Clamp

    SMCJ6.0A at a glance: transient voltage suppressor diode, 6 V standoff, 10.3 V clamp, 145.7 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJ6.0A
    Standoff voltage (VR)6 V
    Leakage current at VR500 uA
    Breakdown voltage at IT6.67 V to 7.37 V
    Test current (IT)10 mA
    Clamping voltage at IPP10.3 V
    Peak pulse current145.7 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.49 percent, from 6.67 V to 7.37 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6 V standing the leakage is at most 500 uA, so the part draws 3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 3 of 155 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products