    SMCJ6.0CA at a glance: transient voltage suppressor diode, 6 V standoff, 10.3 V clamp, 145.7 A pulse, 1500 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMCJ6.0CA
    Standoff voltage (VR)6 V
    Leakage current at VR500 uA
    Breakdown voltage at IT6.67 V to 7.37 V
    Test current (IT)10 mA
    Clamping voltage at IPP10.3 V
    Peak pulse current145.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.49 percent, from 6.67 V to 7.37 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6 V standing the leakage is at most 500 uA, so the part draws 3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 3 of 155 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.