Eaton SMCJ75CAH 75 V 1500 W TVS Diode
Eaton SMCJ75CAH 75 V 1500 W TVS Diode

Eaton SMCJ75CAH 75 V 1500 W TVS Diode

Share
SMCJ75CAH: transient voltage suppressor diode, 75 V standoff, 121 V clamp, 12.4 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton SMCJ75CAH 75 V 1500 W TVS Diode

    SMCJ75CAH at a glance: transient voltage suppressor diode, 75 V standoff, 121 V clamp, 12.4 A pulse, 1500 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJ75CAH
    Standoff voltage (VR)75 V
    Leakage current at VR1 uA
    Breakdown voltage at IT83.3 V to 92.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP121 V
    Peak pulse current12.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1064

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1064; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.56 percent, from 83.3 V to 92.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 75 V standing the leakage is at most 1 uA, so the part draws 0.075 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 94 of 155 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products