Eaton SMCJ9.0A TVS Diode, 15.4 V Clamp
Eaton SMCJ9.0A TVS Diode, 15.4 V Clamp

Eaton SMCJ9.0A TVS Diode, 15.4 V Clamp

Share
SMCJ9.0A: transient voltage suppressor diode, 9 V standoff, 15.4 V clamp, 97.4 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJ9.0A TVS Diode, 15.4 V Clamp

    SMCJ9.0A at a glance: transient voltage suppressor diode, 9 V standoff, 15.4 V clamp, 97.4 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJ9.0A
    Standoff voltage (VR)9 V
    Leakage current at VR30 uA
    Breakdown voltage at IT10 V to 11.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP15.4 V
    Peak pulse current97.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1563

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1563; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 11 percent, from 10 V to 11.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 9 V standing the leakage is at most 30 uA, so the part draws 0.27 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 15 of 155 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products