SMCJE12A: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 75.4 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJE12A Transient Voltage Suppressor 12 V

    SMCJE12A at a glance: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 75.4 A pulse, 1500 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMCJE12A
    Standoff voltage (VR)12 V
    Leakage current at VR1 uA
    Breakdown voltage at IT13.3 V to 14.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP19.9 V
    Peak pulse current75.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.53 percent, from 13.3 V to 14.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 12 V standing the leakage is at most 1 uA, so the part draws 0.012 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 22 of 155 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.