Eaton SMCJE130A Transient Voltage Suppressor 130 V
Eaton SMCJE130A Transient Voltage Suppressor 130 V

Eaton SMCJE130A Transient Voltage Suppressor 130 V

Share
SMCJE130A: transient voltage suppressor diode, 130 V standoff, 209 V clamp, 7.2 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJE130A Transient Voltage Suppressor 130 V

    SMCJE130A at a glance: transient voltage suppressor diode, 130 V standoff, 209 V clamp, 7.2 A pulse, 1500 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMCJE130A
    Standoff voltage (VR)130 V
    Leakage current at VR1 uA
    Breakdown voltage at IT144 V to 159 V
    Test current (IT)1 mA
    Clamping voltage at IPP209 V
    Peak pulse current7.2 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.42 percent, from 144 V to 159 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 130 V standing the leakage is at most 1 uA, so the part draws 0.13 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 116 of 155 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.