Eaton SMCJE170A TVS Diode, 275 V Clamp
Eaton SMCJE170A TVS Diode, 275 V Clamp

Eaton SMCJE170A TVS Diode, 275 V Clamp

Share
SMCJE170A: transient voltage suppressor diode, 170 V standoff, 275 V clamp, 5.5 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJE170A TVS Diode, 275 V Clamp

    SMCJE170A at a glance: transient voltage suppressor diode, 170 V standoff, 275 V clamp, 5.5 A pulse, 1500 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMCJE170A
    Standoff voltage (VR)170 V
    Leakage current at VR1 uA
    Breakdown voltage at IT189 V to 209 V
    Test current (IT)1 mA
    Clamping voltage at IPP275 V
    Peak pulse current5.5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.58 percent, from 189 V to 209 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 170 V standing the leakage is at most 1 uA, so the part draws 0.17 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 125 of 155 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd