Eaton SMCJE30CA 30 V 1500 W TVS Diode
Eaton SMCJE30CA 30 V 1500 W TVS Diode

Eaton SMCJE30CA 30 V 1500 W TVS Diode

Share
SMCJE30CA: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 31 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton SMCJE30CA 30 V 1500 W TVS Diode

    SMCJE30CA at a glance: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 31 A pulse, 1500 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMCJE30CA
    Standoff voltage (VR)30 V
    Leakage current at VR1 uA
    Breakdown voltage at IT33.3 V to 36.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP48.4 V
    Peak pulse current31 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.51 percent, from 33.3 V to 36.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 30 V standing the leakage is at most 1 uA, so the part draws 0.03 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 56 of 155 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.