Eaton SMCJE54CA 54 V 1500 W TVS Diode
Eaton SMCJE54CA 54 V 1500 W TVS Diode

Eaton SMCJE54CA 54 V 1500 W TVS Diode

Share
SMCJE54CA: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 17.2 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton SMCJE54CA 54 V 1500 W TVS Diode

    SMCJE54CA at a glance: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 17.2 A pulse, 1500 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMCJE54CA
    Standoff voltage (VR)54 V
    Leakage current at VR1 uA
    Breakdown voltage at IT60 V to 66.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP87.1 V
    Peak pulse current17.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.5 percent, from 60 V to 66.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 54 V standing the leakage is at most 1 uA, so the part draws 0.054 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 80 of 155 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.