Eaton SMCJE58CA 58 V 1500 W TVS Diode
Eaton SMCJE58CA 58 V 1500 W TVS Diode

Eaton SMCJE58CA 58 V 1500 W TVS Diode

Share
SMCJE58CA: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 16.1 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton SMCJE58CA 58 V 1500 W TVS Diode

    SMCJE58CA at a glance: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 16.1 A pulse, 1500 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMCJE58CA
    Standoff voltage (VR)58 V
    Leakage current at VR1 uA
    Breakdown voltage at IT64.4 V to 71.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP93.6 V
    Peak pulse current16.1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.56 percent, from 64.4 V to 71.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 58 V standing the leakage is at most 1 uA, so the part draws 0.058 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 83 of 155 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products