SMCJE6.5A: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 134 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJE6.5A Transient Voltage Suppressor 6.5 V

    SMCJE6.5A at a glance: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 134 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJE6.5A
    Standoff voltage (VR)6.5 V
    Leakage current at VR150 uA
    Breakdown voltage at IT7.22 V to 7.98 V
    Test current (IT)10 mA
    Clamping voltage at IPP11.2 V
    Peak pulse current134 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.53 percent, from 7.22 V to 7.98 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6.5 V standing the leakage is at most 150 uA, so the part draws 0.975 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 6 of 155 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd