Eaton SMCJE60CA 60 V 1500 W TVS Diode
Eaton SMCJE60CA 60 V 1500 W TVS Diode

Eaton SMCJE60CA 60 V 1500 W TVS Diode

Share
SMCJE60CA: transient voltage suppressor diode, 60 V standoff, 96.8 V clamp, 15.5 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton SMCJE60CA 60 V 1500 W TVS Diode

    SMCJE60CA at a glance: transient voltage suppressor diode, 60 V standoff, 96.8 V clamp, 15.5 A pulse, 1500 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMCJE60CA
    Standoff voltage (VR)60 V
    Leakage current at VR1 uA
    Breakdown voltage at IT66.7 V to 73.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP96.8 V
    Peak pulse current15.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.49 percent, from 66.7 V to 73.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 60 V standing the leakage is at most 1 uA, so the part draws 0.06 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 86 of 155 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd