SMCJE7.0A: transient voltage suppressor diode, 7 V standoff, 12 V clamp, 125 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJE7.0A TVS Diode, 12 V Clamp

    SMCJE7.0A at a glance: transient voltage suppressor diode, 7 V standoff, 12 V clamp, 125 A pulse, 1500 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMCJE7.0A
    Standoff voltage (VR)7 V
    Leakage current at VR100 uA
    Breakdown voltage at IT7.78 V to 8.6 V
    Test current (IT)10 mA
    Clamping voltage at IPP12 V
    Peak pulse current125 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.54 percent, from 7.78 V to 8.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 7 V standing the leakage is at most 100 uA, so the part draws 0.7 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 8 of 155 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.