SMCJE7.5A: transient voltage suppressor diode, 7.5 V standoff, 12.9 V clamp, 116.3 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJE7.5A Transient Voltage Suppressor 7.5 V

    SMCJE7.5A at a glance: transient voltage suppressor diode, 7.5 V standoff, 12.9 V clamp, 116.3 A pulse, 1500 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMCJE7.5A
    Standoff voltage (VR)7.5 V
    Leakage current at VR50 uA
    Breakdown voltage at IT8.33 V to 9.21 V
    Test current (IT)1 mA
    Clamping voltage at IPP12.9 V
    Peak pulse current116.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.56 percent, from 8.33 V to 9.21 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 7.5 V standing the leakage is at most 50 uA, so the part draws 0.375 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 10 of 155 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message