Eaton SMCJE85A TVS Diode, 137 V Clamp
Eaton SMCJE85A TVS Diode, 137 V Clamp

Eaton SMCJE85A TVS Diode, 137 V Clamp

Share
SMCJE85A: transient voltage suppressor diode, 85 V standoff, 137 V clamp, 11 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton SMCJE85A TVS Diode, 137 V Clamp

    SMCJE85A at a glance: transient voltage suppressor diode, 85 V standoff, 137 V clamp, 11 A pulse, 1500 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMCJE85A
    Standoff voltage (VR)85 V
    Leakage current at VR1 uA
    Breakdown voltage at IT94.4 V to 104 V
    Test current (IT)1 mA
    Clamping voltage at IPP137 V
    Peak pulse current11 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11215

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11215; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.17 percent, from 94.4 V to 104 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 85 V standing the leakage is at most 1 uA, so the part draws 0.085 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMCJ family this is item 101 of 155 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products