    SMDJ14CA at a glance: transient voltage suppressor diode, 14 V standoff, 23.2 V clamp, 129.3 A pulse, 3000 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMDJ14CA
    Standoff voltage (VR)14 V
    Leakage current at VR2 uA
    Breakdown voltage at IT15.6 V to 17.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP23.2 V
    Peak pulse current129.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1562

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1562; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.26 percent, from 15.6 V to 17.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 14 V standing the leakage is at most 2 uA, so the part draws 0.028 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 27 of 123 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.