Eaton SMDJ17A TVS Diode, 27.6 V Clamp
Eaton SMDJ17A TVS Diode, 27.6 V Clamp

Eaton SMDJ17A TVS Diode, 27.6 V Clamp

Share
SMDJ17A: transient voltage suppressor diode, 17 V standoff, 27.6 V clamp, 108.7 A pulse, 3000 W, unidirectional.
    • Product Details
    • Download

    Eaton SMDJ17A TVS Diode, 27.6 V Clamp

    SMDJ17A at a glance: transient voltage suppressor diode, 17 V standoff, 27.6 V clamp, 108.7 A pulse, 3000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMDJ17A
    Standoff voltage (VR)17 V
    Leakage current at VR2 uA
    Breakdown voltage at IT18.9 V to 20.9 V
    Test current (IT)1 mA
    Clamping voltage at IPP27.6 V
    Peak pulse current108.7 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1562

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1562; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.58 percent, from 18.9 V to 20.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 17 V standing the leakage is at most 2 uA, so the part draws 0.034 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 36 of 123 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.