Eaton SMDJ220A Transient Voltage Suppressor 220 V
Eaton SMDJ220A Transient Voltage Suppressor 220 V

Eaton SMDJ220A Transient Voltage Suppressor 220 V

Share
SMDJ220A: transient voltage suppressor diode, 220 V standoff, 356 V clamp, 8.4 A pulse, 3000 W, unidirectional.
    • Product Details
    • Download

    Eaton SMDJ220A Transient Voltage Suppressor 220 V

    SMDJ220A at a glance: transient voltage suppressor diode, 220 V standoff, 356 V clamp, 8.4 A pulse, 3000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMDJ220A
    Standoff voltage (VR)220 V
    Leakage current at VR2 uA
    Breakdown voltage at IT244 V to 270 V
    Test current (IT)1 mA
    Clamping voltage at IPP356 V
    Peak pulse current8.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1562

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1562; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.66 percent, from 244 V to 270 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 220 V standing the leakage is at most 2 uA, so the part draws 0.44 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 122 of 123 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products