Eaton SMDJ36CA 36 V 3000 W TVS Diode
Eaton SMDJ36CA 36 V 3000 W TVS Diode

Eaton SMDJ36CA 36 V 3000 W TVS Diode

Share
SMDJ36CA: transient voltage suppressor diode, 36 V standoff, 58.1 V clamp, 51.6 A pulse, 3000 W, bidirectional.
    • Product Details
    • Download

    Eaton SMDJ36CA 36 V 3000 W TVS Diode

    SMDJ36CA at a glance: transient voltage suppressor diode, 36 V standoff, 58.1 V clamp, 51.6 A pulse, 3000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMDJ36CA
    Standoff voltage (VR)36 V
    Leakage current at VR2 uA
    Breakdown voltage at IT40 V to 44.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP58.1 V
    Peak pulse current51.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1562

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1562; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.5 percent, from 40 V to 44.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 36 V standing the leakage is at most 2 uA, so the part draws 0.072 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 63 of 123 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.