Eaton SMDJ40CAH 40 V 3000 W TVS Diode
Eaton SMDJ40CAH 40 V 3000 W TVS Diode

Eaton SMDJ40CAH 40 V 3000 W TVS Diode

Share
SMDJ40CAH: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 46.5 A pulse, 3000 W, bidirectional.
    • Product Details
    • Download

    Eaton SMDJ40CAH 40 V 3000 W TVS Diode

    SMDJ40CAH at a glance: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 46.5 A pulse, 3000 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMDJ40CAH
    Standoff voltage (VR)40 V
    Leakage current at VR5 uA
    Breakdown voltage at IT44.4 V to 49.1 V
    Test current (IT)5 mA
    Clamping voltage at IPP64.5 V
    Peak pulse current46.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1065

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1065; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.59 percent, from 44.4 V to 49.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 40 V standing the leakage is at most 5 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 67 of 123 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.