Eaton SMDJ45AH TVS Diode, 72.7 V Clamp
Eaton SMDJ45AH TVS Diode, 72.7 V Clamp

Eaton SMDJ45AH TVS Diode, 72.7 V Clamp

Share
SMDJ45AH: transient voltage suppressor diode, 45 V standoff, 72.7 V clamp, 41.3 A pulse, 3000 W, unidirectional.
    • Product Details
    • Download

    Eaton SMDJ45AH TVS Diode, 72.7 V Clamp

    SMDJ45AH at a glance: transient voltage suppressor diode, 45 V standoff, 72.7 V clamp, 41.3 A pulse, 3000 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMDJ45AH
    Standoff voltage (VR)45 V
    Leakage current at VR5 uA
    Breakdown voltage at IT50 V to 55.3 V
    Test current (IT)5 mA
    Clamping voltage at IPP72.7 V
    Peak pulse current41.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1065

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1065; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.6 percent, from 50 V to 55.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 45 V standing the leakage is at most 5 uA, so the part draws 0.225 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 73 of 123 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.