Eaton SMDJ54A Transient Voltage Suppressor 54 V
Eaton SMDJ54A Transient Voltage Suppressor 54 V

Eaton SMDJ54A Transient Voltage Suppressor 54 V

Share
SMDJ54A: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 34.4 A pulse, 3000 W, unidirectional.
    • Product Details
    • Download

    Eaton SMDJ54A Transient Voltage Suppressor 54 V

    SMDJ54A at a glance: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 34.4 A pulse, 3000 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMDJ54A
    Standoff voltage (VR)54 V
    Leakage current at VR2 uA
    Breakdown voltage at IT60 V to 66.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP87.1 V
    Peak pulse current34.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1562

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1562; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.5 percent, from 60 V to 66.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 54 V standing the leakage is at most 2 uA, so the part draws 0.108 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 81 of 123 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd