Eaton SMDJE100A Transient Voltage Suppressor 100 V
Eaton SMDJE100A Transient Voltage Suppressor 100 V

Eaton SMDJE100A Transient Voltage Suppressor 100 V

Share
SMDJE100A: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 18.5 A pulse, 3000 W, unidirectional.
    • Product Details
    • Download

    Eaton SMDJE100A Transient Voltage Suppressor 100 V

    SMDJE100A at a glance: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 18.5 A pulse, 3000 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMDJE100A
    Standoff voltage (VR)100 V
    Leakage current at VR1 uA
    Breakdown voltage at IT111 V to 123 V
    Test current (IT)1 mA
    Clamping voltage at IPP162 V
    Peak pulse current18.5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11217

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11217; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.81 percent, from 111 V to 123 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 100 V standing the leakage is at most 1 uA, so the part draws 0.1 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 101 of 123 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.