Eaton SMDJE100CA 100 V 3000 W TVS Diode
Eaton SMDJE100CA 100 V 3000 W TVS Diode

Eaton SMDJE100CA 100 V 3000 W TVS Diode

Share
SMDJE100CA: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 18.5 A pulse, 3000 W, bidirectional.
    • Product Details
    • Download

    Eaton SMDJE100CA 100 V 3000 W TVS Diode

    SMDJE100CA at a glance: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 18.5 A pulse, 3000 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMDJE100CA
    Standoff voltage (VR)100 V
    Leakage current at VR1 uA
    Breakdown voltage at IT111 V to 123 V
    Test current (IT)1 mA
    Clamping voltage at IPP162 V
    Peak pulse current18.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11217

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11217; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.81 percent, from 111 V to 123 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 100 V standing the leakage is at most 1 uA, so the part draws 0.1 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 101 of 123 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.